Independent Testing & Validation


Magnom has been validated through independent testing.
In long-term field trials across hydraulic, transmission, and power generation systems.
Testing has been conducted by recognised third-party organisations, with no influence from Magnom on test methods or outcomes.
Results consistently demonstrate effective removal of damaging ferrous contamination without flow restriction, providing transparent, data-driven evidence of performance in real operating conditions.
SSI Dynamic Filtration Efficiency (DFE) 'single pass' testing, MAGNOM Core Technology Summary of results
Application: Hydraulic systems (Dynamic filter efficiency testing)
Objective: Quantify contaminant capture and efficiency
Key Findings:
- Demonstrated high ferrous capture efficiency
- Sustained performance under continuous circulation
Outcome: Independent confirmation of separation effectiveness

Differential Pressure Test, BY ‘Bosch Rexroth’ Independent

Application: Hydraulic pump suction lines
Objective: Confirm pressure differential performance of the Magnom PumpMate suction filter under clean and fully contaminated conditions.
Key Findings:
-
Ultra-low pressure differential at operating flow.
-
No measurable increase in pressure drop when fully loaded.
-
Performance remained within pump manufacturer inlet limits.
Outcome: Independent validation that Magnom PumpMate delivers consistent, low-loss suction filtration without compromising pump performance.
Magnom Filter Trial at BSL Western Port
Application: Industrial hydraulic systems (steel processing environment)
Objective: Assess the impact of Magnom filtration on wear debris capture and system cleanliness under real operating conditions.
Key Findings:
-
Significant reduction in ferrous wear debris.
-
Improved oil cleanliness during normal production.
-
No adverse impact on system operation or flow.
Outcome: Independent site trial confirming Magnom filtration effectiveness in reducing wear contamination and supporting reliable hydraulic system performance

Global OEM compares Magnom

Application: Hydraulic pump suction lines
Objective: Compare Magnom PumpMate suction filtration performance against conventional suction strainers.
Key Findings:
-
Conventional suction filters are limited to ~125 micron capture, while the most damaging wear particles are 1–40 micron.
-
Magnom captures sub-micron ferrous particles with fit-for-life capacity.
-
Ferrous particle counts were reduced across all particle sizes.
Outcome: Magnom PumpMate demonstrated significantly superior ferrous removal versus conventional suction strainers and was adopted as the group standard, replacing inadequate legacy filtration.
Magnom Filter at Didcot PowerStation
Application: Power generation plant lubrication and hydraulic systems (coal mill transmissions)
Objective: Evaluate the impact of Magnom™ magnetic separation on wear reduction, asset life extension, and plant availability.
Key Findings:
-
Removal of sub-micron, hard ferrous contaminants interrupted the wear recirculation cycle.
-
Transmission life was significantly extended.
-
Mill availability and power generation uptime increased.
-
Substantial operational cost savings were achieved.
Outcome: Compelling life extension and availability gains justified plant-wide adoption of Magnom™ across critical systems, delivering annual savings of hundreds of thousands of pounds per mill from a typical installation cost of approximately £5k.

REXROTH & Magnom prove the value of Pre Pump, Suction filtration

Application: Hydraulic pump suction-side filtration (Bosch Rexroth variable piston pump systems)
Objective: Evaluate the effectiveness and suitability of Magnom PumpMate as the sole pre-pump suction filtration solution on an OEM hydraulic power unit.
Key Findings:
-
Aggressive micron and sub-micron ferrous contaminants were removed pre-pump.
-
System cleanliness achieved NAS 3, despite PumpMate being the only filtration.
-
No restriction to flow and no cavitation risk, even when fully loaded.
-
Maintained identical flow performance when clean and contaminated.
-
Removal of some non-ferrous contamination was also observed.
-
Demonstrated compatibility with Bosch Rexroth warranty requirements.
Outcome: Independent testing with Bosch Rexroth validated Magnom PumpMate as a non-restrictive, fit-for-life suction filtration solution, leading to Rexroth ‘AB’ best-practice approval and official product showcase at the Hannover Fair.
Global OEM, Off Highway epicyclic transmission filtration development & testing
Application: Off-highway epicyclic transmission systems (OEM development and durability testing)
Objective: Validate a pre-pump suction filtration solution to extend transmission life, improve reliability and availability, and reduce service frequency and ownership cost.
Key Findings:
- Aggressive micron and sub-micron ferrous contamination was removed pre-pump.
- Approximately 20 g of ferrous debris was captured that would have passed through a 125 µm suction strainer.
- Following severe overheating due to a sensor fault, all transmission components remained within tolerance with no abnormal wear.
- Pump white-metal bearings showed no distress, contrary to typical failure indicators at equivalent test hours.
Outcome: OEM testing confirmed Magnom magnetic core technology as an effective, non-restrictive suction filtration solution with clear benefits to component life, system reliability, and warranty risk reduction.

HYDAC Magnetic Filtration test

Application: Hydraulic filtration systems using HYDAC LF60, LF110 & LF240 filter housings
Objective: Independently evaluate the effectiveness and flow behaviour of Magnom magnetic core technology when integrated into standard HYDAC filter housings.
Key Findings:
-
Complete removal of micro-fine ferrous contamination from laboratory test fluids was observed.
-
The majority of contamination was captured at the initial fluid entry into the magnetic core stack, with progressively reduced contamination through the core.
-
Flow channels remained clean and unobstructed, even when the magnetic core was fully loaded with contamination.
-
Captured contamination remained retained within the magnetic traps and was not re-entrained into the fluid.
-
Negligible pressure differential was measured across the magnetic core, indicating non-restrictive flow behaviour.
Outcome: HYDAC laboratory testing confirmed Magnom magnetic core technology provides highly effective ferrous contamination removal without flow restriction, validating its suitability for both pressure and suction-side filtration applications without cavitation risk.
Global OEM, Off Highway epicyclic transmission filtration development & testing
Application: High-viscosity transmission lubricant filtration
(Automatic transmission systems – laboratory bench testing and in-service field evaluation)
Objective: Evaluate Magnom magnetic separation performance in high-viscosity transmission fluids, including contaminant removal effectiveness and confirmation that additive chemistry is not adversely affected.
Key Findings:
-
Iron contamination was reduced from ~450 ppm to ~25 ppm in high-viscosity lubricant, as confirmed by ExxonMobil oil analysis data.
-
Removal of ferrous debris significantly reduced secondary wear generation, interrupting the abrasive wear chain reaction.
-
Bench testing with 10 µm and smaller iron particles demonstrated Magnom captured approximately 6,000 mg of contamination, substantially outperforming conventional spin-on filters.
-
Contamination captured included both ferrous and agglomerated non-ferrous wear metals, resulting in reduced aluminium, copper, lead, and tin levels.
-
No statistically significant change was observed in lubricant additive levels following Magnom™ installation.
Outcome: Independent testing with ExxonMobil oil analysis and Allison Transmission systems confirmed Magnom provides highly effective ferrous contamination control in high-viscosity transmission fluids without removing additive chemistry, delivering significant reductions in wear metals and improved transmission protection beyond conventional filtration.