Examples of wear [page 4 of 'ferrous particle problem']

This page contains some examples of modern fluid systems.

It shows the locations at which wear occurs and the typical dynamic tolerances we need to consider when trying to filter ‘dangerous’ ferrous particles to stop the chain reaction of wear.

Gear Pump


Dynamic Clearance Tooth to side plate: 0.5 - 5 microns
Tooth tip to case: 0.5 - 5 microns

Vane Pump


Dynamic clearance vane sides: 5 - 13 microns
Dynamic clearance vane tip: 0.5 - 1 microns

Piston Pump


Dynamic clearance piston to bore: 5 - 40 microns
Dynamic clearance valve plate to cylinder: 0.5 - 5 microns

Typical Valve


Dynamic Clearance 2 - 20 microns

back to top

Micro ferrous particles account for the majority of failures in fluid systems.

Magnom™ Magnetic Filters remove ferrous particles from a wide range of fluids:

and more...

Alliance, association & collaboration

As leading specialists in magnetic filtration & separation, we offer an active R & D program to leading OEM's.

Let us set Magnom™ to work inside your systems.